Product Advantage
1.This charger is certified with CE, UL, FCC, CSA, KC etc, and complies with relevant requirements for electromagnetic compatibility and safety.
2.Touch and leakage current values remain within required limits, without further measures.
3.The power factor is 0.99, therefore the available mains power is used to the maximum.
4.The charging current contains a very low ripple.
5.Charging from single or three-phase outlet.
6.Parallel connection of several chargers is possible, in order to achieve higher charging power.
7.Highly efficient (Max 95%).
8.Core Power Module is IP 67 Protection level, robust against dust, humidity, vibration etc.
Dimension:
Specifications:
Model | FST-C-36150-3BF | |
Rated Input Voltage Range | 3P 380/440/480VAC 1P 380VAC | |
Rated input frequency | 45-65Hz | |
Input power | ≤10.5KVA | |
Input current(Max) | 18A @3P380VAC 16A @3P440VAC 15A @3P480VAC 18A @1P380VAC | |
Maximum conversion efficiency | ≥95% | |
Rated output voltage | 36V | |
Max output current | 150A | |
Output voltage range | 15-48VDC | |
Max output power | 10KW | |
Communication | CAN BUS | |
Cooling method | Fans cooling | |
Operating temperature | -30°C to 50°C. Over 50 °C Derate | |
Relative humidity | 0%-95% | |
Protection level | IP67 | |
Noise | ≤20dB | |
Altitude | Below 2000m. | |
Weight | 10KG |
Basic Function
The First Power OBC converts three-phase AC into DC while maintaining galvanic isolation between the public AC grid and the industrial fleet's DC system. This setup enables efficient battery charging while ensuring safety for both grids. Control over battery charging is managed via CAN, with the charger regulating current and voltage according to CAN-provided values. As a protective measure, if no CAN signals are received for approximately 0.2 seconds, the unit suspends charging to safeguard the battery.
Our on-board charger provides the ideal solution for ensuring your industrial fleet remains powered and operational. Equipped with advanced charging technology, it offers fast and efficient charging, guaranteeing your batteries reach full capacity quickly. Designed for durability, the charger boasts rugged construction and high-quality components engineered to withstand even the most challenging environments. Whether you operate forklifts or AWP equipment, our on-board charger delivers reliable and efficient performance. Don't hesitate—place your order today to experience its unmatched power and functionality!
Product Advantage
1.This charger is certified with CE, UL, FCC, CSA, KC etc, and complies with relevant requirements for electromagnetic compatibility and safety.
2.Touch and leakage current values remain within required limits, without further measures.
3.The power factor is 0.99, therefore the available mains power is used to the maximum.
4.The charging current contains a very low ripple.
5.Charging from single or three-phase outlet.
6.Parallel connection of several chargers is possible, in order to achieve higher charging power.
7.Highly efficient (Max 95%).
8.Core Power Module is IP 67 Protection level, robust against dust, humidity, vibration etc.
Dimension:
Specifications:
Model | FST-C-36150-3BF | |
Rated Input Voltage Range | 3P 380/440/480VAC 1P 380VAC | |
Rated input frequency | 45-65Hz | |
Input power | ≤10.5KVA | |
Input current(Max) | 18A @3P380VAC 16A @3P440VAC 15A @3P480VAC 18A @1P380VAC | |
Maximum conversion efficiency | ≥95% | |
Rated output voltage | 36V | |
Max output current | 150A | |
Output voltage range | 15-48VDC | |
Max output power | 10KW | |
Communication | CAN BUS | |
Cooling method | Fans cooling | |
Operating temperature | -30°C to 50°C. Over 50 °C Derate | |
Relative humidity | 0%-95% | |
Protection level | IP67 | |
Noise | ≤20dB | |
Altitude | Below 2000m. | |
Weight | 10KG |
Basic Function
The First Power OBC converts three-phase AC into DC while maintaining galvanic isolation between the public AC grid and the industrial fleet's DC system. This setup enables efficient battery charging while ensuring safety for both grids. Control over battery charging is managed via CAN, with the charger regulating current and voltage according to CAN-provided values. As a protective measure, if no CAN signals are received for approximately 0.2 seconds, the unit suspends charging to safeguard the battery.
Our on-board charger provides the ideal solution for ensuring your industrial fleet remains powered and operational. Equipped with advanced charging technology, it offers fast and efficient charging, guaranteeing your batteries reach full capacity quickly. Designed for durability, the charger boasts rugged construction and high-quality components engineered to withstand even the most challenging environments. Whether you operate forklifts or AWP equipment, our on-board charger delivers reliable and efficient performance. Don't hesitate—place your order today to experience its unmatched power and functionality!