Availability: | |
---|---|
Quantity: | |
FST-C-35025-3CN
FIRST POWER
Lithium-ion
On Board
CE, UL, FCC, C-Tick, CSA
Forklift
3P480VAC
350V
Product Advantage
1.This charger is certified with CE, UL, FCC, CSA, KC etc, and complies with relevant requirements for electromagnetic compatibility and safety.
2.Touch and leakage current values remain within required limits, without further measures.
3.The power factor is 0.99, therefore the available mains power is used to the maximum.
4.The charging current contains a very low ripple.
5.Charging from single or three-phase outlet.
6.Parallel connection of several chargers is possible, in order to achieve higher charging power.
7.Highly efficient (Max 95%).
8.Core Power Module is IP 67 Protection level, robust against dust, humidity, vibration etc.
Dimension:
Specifications:
Model | FST-C-35025-3CN | |
Rated Input Voltage Range | 3P 380/440/480VAC,1P 110/120/220/240VAC | |
Rated input frequency | 45-65Hz | |
Input power | ≤10.5KVA | |
Input current(Max) | 18A @3P380VAC 16A @3P440VAC 15A @3P480VAC 16A @1P110/120VAC 31A @1P220/240VAC | |
Maximum conversion efficiency | ≥95% | |
Rated output voltage | 350V | |
Max output current | 25A | |
Output voltage range | 136-450VDC | |
Max output power | 10KW | |
Communication | CAN BUS | |
Cooling method | Nature cooling | |
Operating temperature | -30°C to 50°C. Over 50 °C Derate | |
Relative humidity | 0%-95% | |
Protection level | IP67 | |
Noise | ≤20dB | |
Altitude | Below 2000m. | |
Weight | 9KG |
Basic Function
The First Power OBC converts both single-phase and three-phase alternating current into direct current while maintaining galvanic isolation between the public AC grid and the industrial fleet's DC system. This setup enables efficient battery charging while ensuring the safety of both grids. The CAN protocol governs battery charging, with the charger regulating current and voltage according to CAN-provided values. As a protective measure, if no CAN signals are received for approximately 0.2 seconds, the unit suspends the charging process to safeguard the battery.
Our on-board charger is the ultimate solution for maintaining your industrial fleet's power and readiness. Featuring advanced charging technology, it provides rapid and efficient charging, ensuring your batteries reach full capacity quickly. Built with durability in mind, the charger boasts rugged construction and high-quality components engineered to withstand even the most challenging environments. Whether you need reliable power for forklifts or AWP equipment, our on-board charger is the ideal choice. Don't wait—place your order today and discover the unparalleled power and performance it delivers!
Product Advantage
1.This charger is certified with CE, UL, FCC, CSA, KC etc, and complies with relevant requirements for electromagnetic compatibility and safety.
2.Touch and leakage current values remain within required limits, without further measures.
3.The power factor is 0.99, therefore the available mains power is used to the maximum.
4.The charging current contains a very low ripple.
5.Charging from single or three-phase outlet.
6.Parallel connection of several chargers is possible, in order to achieve higher charging power.
7.Highly efficient (Max 95%).
8.Core Power Module is IP 67 Protection level, robust against dust, humidity, vibration etc.
Dimension:
Specifications:
Model | FST-C-35025-3CN | |
Rated Input Voltage Range | 3P 380/440/480VAC,1P 110/120/220/240VAC | |
Rated input frequency | 45-65Hz | |
Input power | ≤10.5KVA | |
Input current(Max) | 18A @3P380VAC 16A @3P440VAC 15A @3P480VAC 16A @1P110/120VAC 31A @1P220/240VAC | |
Maximum conversion efficiency | ≥95% | |
Rated output voltage | 350V | |
Max output current | 25A | |
Output voltage range | 136-450VDC | |
Max output power | 10KW | |
Communication | CAN BUS | |
Cooling method | Nature cooling | |
Operating temperature | -30°C to 50°C. Over 50 °C Derate | |
Relative humidity | 0%-95% | |
Protection level | IP67 | |
Noise | ≤20dB | |
Altitude | Below 2000m. | |
Weight | 9KG |
Basic Function
The First Power OBC converts both single-phase and three-phase alternating current into direct current while maintaining galvanic isolation between the public AC grid and the industrial fleet's DC system. This setup enables efficient battery charging while ensuring the safety of both grids. The CAN protocol governs battery charging, with the charger regulating current and voltage according to CAN-provided values. As a protective measure, if no CAN signals are received for approximately 0.2 seconds, the unit suspends the charging process to safeguard the battery.
Our on-board charger is the ultimate solution for maintaining your industrial fleet's power and readiness. Featuring advanced charging technology, it provides rapid and efficient charging, ensuring your batteries reach full capacity quickly. Built with durability in mind, the charger boasts rugged construction and high-quality components engineered to withstand even the most challenging environments. Whether you need reliable power for forklifts or AWP equipment, our on-board charger is the ideal choice. Don't wait—place your order today and discover the unparalleled power and performance it delivers!